MIL-STD-1605A(SH)
FIGURE 1. Phase I test limit for topside ambient RF environment.
5.1.1 Phase I preliminary examination. Prior to executing the Phase I measurements an examination shall confirm that:
a. Bonding, grounding, and other techniques for EMC and safety have been accomplished in accordance with
MIL-STD-1310 and/or other contractual documents;
b. Applicable multi-couplers, filters, and blankers are installed and operating; and
c. There are no missing or visibly defective electronic equipments or broken or missing antennas/transmission lines.
Deficiencies discovered during the examination shall be corrected prior to starting Phase I measurement testing.
5.1.2 RF sensor-type equipments requiring testing. RF sensor-type equipments are any device that senses or receives the electromagnetic spectrum from 2 MHz to 460 MHz topside (MF, HF, VHF, UHF) and 2 MHz to 6 GHz below deck, which includes receivers in fixed and mobile devices below deck, mobile wireless systems, Radio Frequency Identification Devices (RFID) readers/transceivers (except those attached to ordnance), wireless data links, all of which may be susceptible to unintentional RF emissions from electrical/electronic equipment and systems. For ships undergoing a modernization/overhaul, only those sensors that may be impacted by changes affected during the modernization/overhaul need be measured.