MAST LEG OR TRUNK SUPPORTING STRUCTURE
CONDUIT ADDED TO UNSHIELDED CABLE
TYPICAL
END CAP
NOTES:
SINGLE CABLE
BREAKOUT
3
MULTI-CABLE BREAKOUT
BOX
CABLE SHIELD GROUNDED
WITHIN STUFFING TUBE
1 2
TRUNK COVER
BUTT PLATE OR
LAP PLATE
TRUNK CABLES SHIELDED/
UNSHIELDED
1. BASIC TRUNK DESIGN SHALL BE IN ACCORDANCE WITH 5.3.1.3
AFTER CABLE TYPES, AND GROUNDING AND SHIELDING REQUIREMENTS HAVE BEEN DETERMINED.
2. FABRICATE END CAP AND BREAKOUT BOXES, AS REQUIRED, TO ACCOMODATE THE NUMBER AND TYPE OF CABLES THAT EXIT THE WIREWAY TRUNK. HOLES SHALL BE SIZED TO FIT THE REQUIRED STUFFING TUBES AND CONDUIT TERMINATION FITTINGS.
3. INSTALL CABLES FROM BELOW DECK EQUIPMENT TO TOPSIDE EQUIP- MENT LOCATION THROUGH END CAPS, BREAKOUT BOXES, STUFFING TUBES AND HOLES FOR CONDUIT FITTINGS.
4. CONDUIT TERMINATION FITTINGS OR BULKHEAD FEED THRU FITTINGS MAY BE USED FOR CABLE EXIT IN LIEU OF STANDARD SWAGE TUBES.
5. MEASURE AND CUT SHIELDING CONDUIT TO LENGTHS REQUIRED.
6. INSTALL CABLE SHIELD GROUNDING MATERIALS AND FLEXIBLE SHIELDING CONDUIT AS SPECIFIED HEREIN. WEATHERPROOF ALL FITTINGS AS SPECIFIED FOR CORROSION PROTECTION.
7. ALL FITTINGS ARE DEPICTED PRIOR TO WEATHERPROOFING.
8. AFTER COVERS ARE INSTALLED, WIREWAY TRUNK SHALL BE PRIMED AND PAINTED.
FIGURE 2. Typical wireway trunk.