MOUNTING BRACKET
SHIP HULL/GROUND
3
PLASTIC LIGHT FIXTURE
NOTES:
2 |
1. |
THIS METHOD SHALL BE USED TO GROUND CONDUIT TERMINATING AT NONMETALLIC FIXTURES. |
|
2. |
CONDUIT FITTING SHALL MAKE PERIPHERAL CONTACT WITH A TYPE |
||
II CRES BOND STRAP. |
|||
1 |
3. |
THE BOND STRAP WILL BE CONNECTED TO THE SHIP/HULL GROUND. THE BOND STRAP/HULL MATING SURFACE SHALL BE PREPARED IN ACCORDANCE |
|
WITH 5.1.3.1.c. |
3
BOLT END
CONDUIT END
TYPICAL BOND STRAP LENGTH-TO-WIDTH RATIO
5-TO-1 MAXIMUM
FIGURE 7. Cable shielding method, flexible metal conduit.